Sixnet® I/O Tool Kit Revision History
Jump to series:
5.1.102
2022-04-04
ID | Subject | Description |
---|---|---|
458 | Tool kit | Releasing VT-MIPm-138-D and VT-MIPm-248-D. |
ID | Subject | Description |
---|---|---|
460 | Tool kit | The secondary controller in redundancy can have any station name and not necessarily _bak. |
462 | Tool kit | Any invalid E2 module & base pairing is readback as Mix modoule. |
5.1.101
2022-02-25
ID | Subject | Description |
---|---|---|
456 | Toolkit | The Toolkit should accept and load FWs0100.bin as E2-16DISOE firmware file. |
5.1.100
2021-08-14
ID | Subject | Description |
---|---|---|
359 | Tool kit | Added E2-16DI24-HV, E2-16DISoE-HV and E2-16ISO20M-HV Module in ST-IPM-8460 and Tool kit. |
358 | E2 Firmware version 2.09 and Web UI version 1.20 | Added support for E2-16DI24-HV and E2-16ISO20M-HV. |
360 | Calibration is disabled for E2-16ISO20M-HV | Calibration of E2-16ISO20M-HV module is disabled. |
361 | Analog Options is configurable in 16DI24-HV Web UI | “Analog input integration” option is removed from the Analog Options in the WebUI of 16DI24-HV module. |
362 | Screw terminal assignment for 16DI24-HV & 16ISO20M-HV | In WebUI the Screw Terminal Assignment in Documentation is made available for 16DI24-HV and 16ISO20M-HV modules. |
ID | Subject | Description |
---|---|---|
456 | Toolkit | The Toolkit should accept and load FWs0100.bin as E2-16DISOE firmware file. |
341 | Digital Input Module(E2-16DI24) | The Issue of the pair of DI channels acting as 32 bit counter even after the deselecting "Report as 32 bit counter result as pair of register" is resolved. |
345 | Format Battery Backed RAM | The issue of COM Port being locked after NVRAM format is resolved. |
389 | Clear Configuration of ST-IPm-8460 | The issue of Toolkit crash during Clear Configuration operation of ST-IPm-8460 is resolved. |
5.0.103
2021-10-27
ID | Subject | Description |
---|---|---|
389 | Tool Kit | The issue of Tool kit crashing on Clear Configuration is resolved. |
345 | Tool Kit | The issue - After NVRAM format the RTU boots up, but cannot communicate with the Toolkit via COM Port- is resolved. |
5.0.102
2021-03-17
ID | Subject | Description |
---|---|---|
201 | Tool kit | Added Red Lion Workbench redundancy support in ST-IPM-8460 and Tool kit. |
321 | Red Lion Workbench | Red Lion Workbench serial support changed from serial Port A to Port B. |
ID | Subject | Description |
---|---|---|
322 | Tool Kit | Unused variables and their values were present in general.config file of ST-IPM-8460. Now these Unused variables values are Null. |
5.0.101
2020-10-05
ID | Subject | Description |
---|---|---|
188 | Tool Kit | Added Icon in Tool kit Menu to open Red Lion Workbench.. |
ID | Subject | Description |
---|---|---|
199 | Tool Kit | When exporting tags from the Tool Kit to Red Lion Workbench project, the Floats were exported as Reals and Longs were exported as DWORDs. Now both are exported as DINT. |
203 | Tool Kit | Fixed the extraction of E2 firmware bundles issue. Now, it can be launched more than once. |
158 | Installation | Tool Kit 5.0.101 can be installed on Windows XP virtual machine. |
214 | Tool Kit | Fixed the Tool Kit Crashing issue, when exporting tags to Red Lion Workbench. |
237 | Tool Kit | Resolved the issue of creating tag description file. |
198 | Red Lion Workbench | Now, Red Lion Workbench Project gets compiled as a Big Endian also. |
180 | Red Lion Workbench | Red Lion Workbench supports serial port. |
5.0.100
2019-11-29
ID | Subject | Description |
---|---|---|
161 | Tool Kit | Added Red Lion Workbench support. |
ID | Subject | Description |
---|---|---|
158 | Installation | Tool Kit 5.0.100 cannot be installed on Windows XP virtual machine. |
4.0.173
2019-07-30
ID | Subject | Description |
---|---|---|
106 | IPM Performance | Updated minimum scan time as 8mSec in E2 configuration. |
ID | Subject | Description |
---|---|---|
38 | User Operations | Fixed User Operations bug related to add and delete user. |
ID | Subject | Description |
---|---|---|
158 | Installation | Tool Kit 4.0.172 and 4.0.173 cannot be installed on Windows XP virtual machine. |
4.0.xxx
2015-08-31
ID | Subject | Description |
---|---|---|
14425 | Modbus | Support configuration of word order in 32-bit registers when communcating via Ethernet. |
14650 | USB | Support COM port numbers greater than nine for communicating with stations. |
ID | Subject | Description |
---|---|---|
4692 | EtherTRAK-2 | In some cases when communicating via Ethernet, it was not possible to "wink" the LED on an EtherTRAK-2 module. |
8407 | ISaGRAF | In some cases the Tool Kit would incorrectly report overlapping tags when exporting to ISaGRAF. |
8411 | SIVM | The start address for SIVM tags was not always saved correctly. |
8684, 11591, 11722, 11806, 12318, 12319, 12322, 13043, 13119, 14545 | Help | Revised numerous help pages. |
9421 | Datalogging | In some cases the datalog server would not start. |
9534 | Datalogging | It was not always possible to delete datalog configurations from the RTU. |
11368 | Datalogging | It was not always possible to load datalog configuration to FLASH. |
12616 | Firmware loading | The timeout used when loading firmware to an RTU has been increased to make the process more robust. |
12701 | AGA | In some cases the AGA configuration window would crash. |
12931 | Installation | Support 64-bit versions of Windows. |
12970, 13880, 14983, 15129, 15136 | Communication | In some cases the helper process six32com would hang or crash resulting in failed communciation between the Tool Kit and the station. |
13109 | Projects | The Tool Kit now stores projects and other data in the directory named in $ProgramData (typically C:\ProgramData ) by default. |
13644 | Connected Stations | In some cases, clicking on a station in the list of connected stations crashed the Tool Kit. |
13646 | IPm | The Tool Kit can no longer download firmware to obsolete RTU models with 8MB of NOR. Some early hardware revisions of ST-IPm-2350, ST-IPm-1350, VT-IPm-1410, VT-IPm-2410, VT-mIPm-241-D, VT-mIPm-131-D, VT-uIPm-431-H, VT-uIPm-441-H, ST-GT-1210, and ET-GT-ST-3 are affected. |
13673 | Datalogging | Large data records sometimes included invalid timestamps or data. |
13745 | I/O Transfers | Modbus register addresses greater than 32000 were not handled correctly. |
13984 | New Station | An invalid serial number was sometimes displayed when creating a new station. |
14195 | I/O Transfers | IP addresses in I/O Transfers were not updated when changes were made elsewhere in the project. |
14222 | I/O Transfers | Remote starting addresses for transfers were incorrectly changed in response to Modbus reconfiguration. |
14260 | I/O Transfers | In some cases extra, blank I/O Transfers were created. |
14462 | Installation | Some DLLs could not be registered or unregistered when installing or uninstalling the Tool Kit. |
14553 | EtherTRAK-2 | In some cases, reading back configuration from an EtherTRAK-2 module displayed incorrect results. |
14681 | Installation | The USB serial driver distributed with the Tool Kit has been signed so it passes stricter security requirements in later versions of Windows. |
14962 | Atomic Configuration | In some cases an atomic configuration package could not be created. |
15019 | Atomic Configuration | In some cases, atomic configuation packages would not load properly into the RTU. |
15027 | Security | Creating firewall configuration for the RTU could sometimes crash the Tool Kit. |
15095 | EtherTRAK-2 | Under conditions of heavy network load, loading firmware to an EtherTRAK-2 module could fail. |
15145 | Port Forwarding | Configuration of Port Forwarding in the RTU has been removed from the Tool Kit. |
3.60.118
2014-04-16
ID | Subject | Description |
---|---|---|
13043 | EtherTRAK-2 | Added 16ISOTC wiring diagram to help. |
12665 | IPm | Optimized clear configuration. |
ID | Subject | Description |
---|---|---|
13211 | IPm | Fixed issue where comm port could become inaccessible after a NVRAM format. |
13118 | IPm | Clarified setting in advanced RTU configuration page. |
13021 | IPm | Improved reliability of changing station numbers. |
12971 | IPm | Improved Datalog configuration readback. |
12970 | EtherTRAK-2 | Addressed occasional communication failures. |
12950 | Tool Kit | Fixed errors loading configuration after formatting battery backed RAM. |
12931 | Firmware Loader | Fixed freeze-up issue when upgrading firmware. |
12919 | Tool Kit | Fixed problem with clearing RTU configuration. |
12912 | Tool Kit | Fixed crash when resetting comm port. |
3.59.134
2014-01-10
ID | Subject | Description |
---|---|---|
12323 | Help | Added help for the SNTP synch bit. |
12322 | Help | Added help for the Datalog status bits. |
12319 | Help | Added help for the Batch loading feature. |
12318 | Help | Added help for UDR-A. |
12011 | Tool Kit | Added scan time information in the EtherTRAK-2 filtering options dropdown for AI modules. |
10917 | Tool Kit | Added datalogging status bit configuration. |
10899 | Tool Kit | Added protection from loading firmware v4.8 or greater to 16MB IPms. |
ID | Subject | Description |
---|---|---|
12627 | Tool Kit | Fixed bug that caused SixTRAK module status LEDs to continue flashing after the module was linked and the project changes were applied. |
12616 | Firmware Loader | Increased timeout in the Tool Kit's firmware loader. |
12615 | Tool Kit | Fixed bug that caused an error when reading the firmware version. |
12570 | Tool Kit | Fixed error in calculation of register counts in the RTU configuration I/O transfers. |
12569 | Test I/O | Fixed error in unit representation for remote I/O modules. |
12526 | Help | Added details to "Restart Reason" in the SIVM help. |
12518 | Tool Kit | Fixed crash issue when creating an atomic configuration package with an invalid .x6m file location. |
12496 | Tool Kit | Fixed default configuration for the E2/EB-MIX24880 to disable the "Use last 8 discrete channels as outputs" option. |
12493 | Help | Fixed typo in SIVM help information. |
12492 | Installation | Updated the Licensing Agreement. |
12489 | Tool Kit | Fixed atomic loading operation to provide a warning if attempting to load an atomic configuration that is too large. |
12477 | Tool Kit | Clarified atomic configuration loading communication errors. |
12461 | Tool Kit | Fixed bug in I/O transfer configuration that would change the remote station number to zero. |
12453 | Tool Kit | Fixed error when reading the station's version information. |
12293 | Tool Kit | Fixed saving of RS-485 settings in old VT stations. |
12221 | Tool Kit | Fixed channel listing errors in main Tool Kit screen. |
12220 | Tool Kit | Fixed trouble importing EtherTRAK-2 tag names into remote I/O tags. |
12209 | Tool Kit | Removed "current hardware revision" listing when loading to an EtherTRAK-2. |
12207 | Help | Updated the SIVM help to include the reset type of SysRstTrig. |
12205 | Help | Updated RTU configuration discrete options help. |
12153 | Tool Kit | Added warning if attempting to load a DSM module to a device which has firmware that does not support it. |
12152 | Tool Kit | Fixed selectability issue of status bits in datalog configuration. |
12016 | Help | Updated the wiring and specifications for EtherTRAK-2 modules. |
12008 | Tool Kit | Fixed flickering mouse-over issue in tree view. |
12006 | Tool Kit | Fixed datalog configuration log rate modification issue. |
12003 | Tool Kit | Fixed inability to Create a new Virtual Module via Tree View. |
12001 | Tool Kit | Fixed issue of "No Remote I/O Links in Project" message appearing multiple times when adding a module to an RTU. |
11999 | Tool Kit | Fixed Icon for ET-GT-ST-3 to match in tree view and "create new module" dialog dropdown. |
11998 | Tool Kit | Fixed issue of name changing from RTU to Gateway Configuration under Tree View. |
11997 | Tool Kit | Fixed issue of tag description info for station status module getting copied from system information module. |
11972 | Tool Kit | Fixed issue of scan time not being saved under remote IO Link. |
11959 | Tool Kit | Fixed issue of serial number and version command errors appearing after performing a clear configuration operation. |
11956 | Test I/O | Fixed issue of AX8-AX15 showing as disabled within Test I/O. |
11938 | Tool Kit | Disabled selection for diagnostic information for EtherTRAK-2s since no diagnostic information would be returned. |
11932 | Tool Kit | Fixed issue of Tool Kit crashing while modifying the number of Analog output registers for EtherTRAK-2 modules. |
11931 | Tool Kit | Fixed issue of ST-DI-CNT-08U configuration reporting that "There are no discrete registers available/enabled on this module." |
11930 | Tool Kit | Fixed issue in the AGA configuration add-on that while assigning tags, the tags are blacked out and it is hard to make assignments correctly. |
11929 | Test I/O | Fixed issue of "Disabled" showing for registers that should not be disabled. |
11928 | Tool Kit | Fixed the issue of the previously loaded project reloading automatically when the user attempts to create a new project. |
11927 | Tool Kit | Fixed the issue of the Network IP settings disappear for EtherTRAK-2 modules when changing between Dual Ethernet Modes and Network 1/2 tabs. |
11919 | Tool Kit | Fixed the issue of the Network IP settings for remote I/O modules not saving when configured from context menu in the tree view. |
11908 | Tool Kit | Fixed the issue of the remote I/O register configuration list behaving oddly if the "Enter" key is pressed while editing the bottom register. |
11907 | Tool Kit | Fixed the issue of Tool Kit crashing when attempting to load an invalid configuration. |
11906 | Tool Kit | Fixed the issue of an invalid configuration being created when changing an RTU from a VT-IPm-1410 to a VT-IPm2m. |
11903 | Tool Kit | Fixed the issue of the EtherTRAK-2 Drop Physical Outputs option becoming enabled for AI Modules after performing a read-back operation. |
11900 | Tool Kit | Fixed the issue of the "Load all now" operation not loading the project archive. |
11899 | Tool Kit | Fixed the issue of text disappearing from the EtherTRAK-2 loading dialog if you click on the window randomly. |
11891 | Tool Kit | Fixed the issue that would cause Tool Kit to crash if there was a blank entry in the I/O transfer table when attempting to download the configuration to the RTU or create an atomic configuration file. |
11860 | Tool Kit | Fixed the issue that would cause a checkbox in the tree views column to not change until you moved the cursor off it. |
11855 | Tool Kit | Fixed the issue that would cause "Unknown analog input range" errors when reading back an E2/EB-16ISOTC configuration. |
11847 | Tool Kit | Fixed the issue that would cause an RTU to not recognize changes to Modbus starting addresses. |
11844 | Tool Kit | Fixed the issue that would cause the mouse pointer to disappear when it was hovering over a "+" on the RTU configuration Advanced tab. |
11837 | Tool Kit | Fixed the issue that would cause the "Time Sync Status bit type" and "Time Sync Status bit address" to be selectable even when "Enable Time Sync Status bit" box was unchecked (which was contrary to specifications). |
11815 | Tool Kit | Fixed the issue that when copying a station to another project, it wouldn't copy the "connected to" information. |
11811 | Tool Kit | For EtherTRAK-2 I/O transfers, the "Create Virtual Module" checkbox was removed since it was not applicable. |
11806 | Firmware Loader | Fixed the help button in the EtherTRAK-2 firmware loader dialog. |
11722 | Help | Added help information to explain why there appears to be a discrepancy between the IP address shown on the Tool Kit status bar and the address shown in the RTU configuration when the IP is calculated automatically. |
11687 | Tool Kit | Fixed the issue of the SIVM values for "Free NVRAM", "Total NVRAM", "Total Datalog Memory", and "Free Datalog Memory" only displaying zeros in Test I/O due to their fractional values. |
7711 | Tool Kit | Fixed the issue of the third and fourth counter timebases not being equivalent for EtherTRAK-2 modules with four high-speed counters. |
3.58.103
2013-07-01
ID | Subject | Description |
---|---|---|
11776 | Tool Kit | Add support for SSH in the ST-IPM-8360. |
11736 | Tool Kit | Add SNTP clock sync status configuration. |
11444 | Tool Kit | Add support for RTUs: ST-IPM-8360, VT-mIPm-138-D, and VT-mIPm-248-D. |
3.57.115
2013-06-07
ID | Subject | Description |
---|---|---|
11647 | Tool Kit | Include the status of the loaded atomic configuration package to the SIVM AI26 value. |
11525 | Tool Kit | Add RTU model ID to atomic configuration package. |
11517 | Tool Kit | Include the CRC of the loaded atomic configuration package to the SIVM L10 value. |
11474 | Tool Kit | Name the file extension for an atomic configuration package to be ".6cp". |
11424 | Tool Kit | Reorganize the atomic configuration menu items. |
11423 | Tool Kit | When selecting stations to create atomic configuration packages for, automatically select the redundant counterpart of redundant pairs. |
11187 | Tool Kit | Only provide the menu options for the CITECT server when it is registered. |
10924 | Tool Kit | Provide Tool Kit executable parameters to create and load atomic configuration packages from the command-line. |
10872 | Tool Kit | Allow Tool Kit to create and maintain the RTU user IDs for auditing purposes. |
10628 | Firmware Loader | Prevent accidental downloading of incompatible firmware to an RTU that contains a large NAND sector size. |
ID | Subject | Description |
---|---|---|
11689 | Tool Kit | Fix error when including a project archive during a configuration load. |
11368 | Datalogging | Fix incorrect firmware version error when the datalog configuration is being loaded to FLASH. |
11268 | Tool Kit | Fix hardware revision error while trying to load a configuration with Channels 3 and 4 as H.S counters on an E2-MIX20884. |
10882 | Tool Kit | Include the missing BEP driver and configuration add-on. |
3.56.126
2013-03-15
ID | Subject | Description |
---|---|---|
11251, 11155, 10870, 10710, 10639, 10612 | RTU | Added configuration of users and additional permissions for authenticated UDR protocol. |
10429 | Tool Kit | Allow relative paths when specifying RTU files to load. |
10355 | RTU | Added functionality for transmitting a configuration package to an RTU. |
9236 | Tool Kit | Increased Tool Kit speed when loading large project files. |
ID | Subject | Description |
---|---|---|
11273 | EtherTRAK-2 | Fix EtherTRAK-2 user configuration so that a deleted user's permissions will not overwrite the "No Login Required" permissions. |
11105 | EtherTRAK-2 | Fix high speed counters for E2-16DI24 and E2-32DI24 modules. |
10492 | EtherTRAK-2 | Added password strength indicator and updated the help file. |
10405 | Tool Kit | Fixed setting corruption if a comma exists in the project file path. |
3.55.102
2012-10-09
ID | Subject | Description |
---|---|---|
10123 | EtherTRAK-2 | Added heartbeat monitoring watchdog features. |
6812 | EtherTRAK-2 | Support dashes in the station names in the main station list. |
ID | Subject | Description |
---|---|---|
10326 | Tool Kit | Improved naming consistency by changing the terminology in the IPm port configuration from "Ethernet1" and "Ethernet2" to "Network 1/Eth0" and "Network 2/Eth1" respectively. |
10325 | Tool Kit | Changed the labels in IPm Advanced Ethernet from "Ethernet1" and "Ethernet2" to "Network 1/Eth0" and "Network 2/Eth1" respectively. |
10324 | Tool Kit | Changed the text in the IPm redundancy configuration window from "Eth0" and "Eth1" to "Network 1/Eth0" and "Network 2/Eth1" respectively. |
10256 | Tool Kit | Fixed bug that caused the initial discrete and analog output addresses to start at "-1" when a VT-IPm-1410 contained a remote link to a RM-RTU-8440 module. |
3.54.109
2012-08-10
ID | Subject | Description |
---|---|---|
10156 | Installation | Changed the Tool Kit installer and uninstaller icons to be aesthetically more appealing. |
9665 | Tool Kit | Changed the Tool Kit icon to be aesthetically more appealing. |
9242 | Tool Kit | Added the ability to delete more than one I/O transfer at once. |
9237 | Tool Kit | Added the ability to delete more than one module at once. |
ID | Subject | Description |
---|---|---|
10133 | Tool Kit | Enabled Lead and Lag time entries for the IPm RS-485 port configuration. |
10058 | Tool Kit | Fixed crashing problem after multiple "Read Back" operations. |
9966 | Tool Kit | Disabled ineffective scaling values for I/O types LI, LO, FI, and FO. This helps to prevent some confusion about their operation. |
9936 | Datalogging | Fixed the minimum log rate for the VT-IPm2m-113/213 so that it can be set below 200ms. |
9905 | ISaGRAF | In ISaGRAF export: Fixed bug that always selected FIs for SIVM, removed redundant backup stations, and changed the maximum number of channels per device from 32 to 128. |
9851 | Datalogging | Fixed a bug that would attempt to load SiteTRAK/RemoteLog sixlog datalog configurations the same way as IPms resulting in error code 0x02. |
9823 | Firmware Loader | Fixed error when updating firmware from a zip file using Ethernet-only connection. |
9793 | ISaGRAF | Automatically correct various ISaGRAF project file errors and discrepancies that could cause problems opening and running them. |
9768 | Tool Kit | Fixed Modbus communications failure over RS-485 at certain baud rates on EtherTRAK-2 modules. |
9767 | Tool Kit | Fixed blank default module name when copying to another project. |
9765, 8712 | Tool Kit | Fixed error when copying a module from an IPm to an IPm in another project. |
9697 | Tool Kit | Fixed loading old projects which have IPms with on-board analog outputs and counters. |
9673 | Tool Kit | Set default number of decimals to six for floating point inputs and outputs. |
9658 | Tool Kit | Added descriptive error when Tool Kit upgrade file creation fails. |
9652 | Datalogging | Fixed issue with datalogging that caused corruption of date stamps and data misalignment and also caused triggered events to to report incorrect discrete values. |
9534 | Tool Kit | Fix mismatch between main datalog list and load advanced list. |
9512 | ISaGRAF | Fixed debugging errors that would occur when running an ISaGRAF project that was created using an earlier version of ISaGRAF. |
9482 | Tool Kit | Fixed issue with E2/EB-10RTD, E2/EB-8ISOTC, and E2/EB-16ISOTC resetting their scale values back to defaults after being configured. |
9236 | Tool Kit | Set preferred base addresses for Tool Kit DLLs. |
8975 | Help | Clarified SIVM information within the standard Tool Kit help. |
8871 | Tool Kit | Fix invalid component update message during Tool Kit startup if ISaGRAF had been uninstalled. |
7288 | Help | Fixed problem with help for the "Copy Prior" button while configuring tags. |
3.53.109
2012-04-13
ID | Subject | Description |
---|---|---|
6251 | Firmware Loader | Added the ability to find the matching firmware image file within a zip archive containing files for multiple IPm types. |
9005 | Tool Kit | Add warning for consecutive underscores in tag names. |
9013 | Installation | Add Windows 7 USB-to-serial driver support. |
8975 | Help | Add SIVM information to the standard Tool Kit help. |
ID | Subject | Description |
---|---|---|
9587 | Tool Kit | Fixed invalid starting DI/DO values for new module configurations added to IPms. |
9421 | Datalog | Fixed "Server not registered" error when starting the datalog server. |
9531 | Datalog | Fixed Tool Kit crash when reading back datalog configuration information from a redundant station. |
9412 | Installation | Fixed installation and registering of HTML Help components. |
9508 | Tool Kit | Fixed display of secondary IP information in IPm redundant controller options if there is no second Ethernet port. |
6429 | Tool Kit | Fixed Ethernet communication failure while running in 64-bit Windows 7. |
9502 | Tool Kit | Fixed inter-station duplicate tag name error detection failure. |
9384 | Installation | Fixed installation issues regarding uninstallation and updating new software components. |
9013 | USB Driver | Eliminated failure message in log listing when installing in 64-bit Windows 7. |
9330 | Tool Kit | Port settings are retained when changing a station type to another compatible type (for example, changing a VT-MIPM-131-D to a VT-MIPM-135-D). |
9331 | Tool Kit | Analog scaling settings are retained when changing the station type between a VT-MIPM-131-D and a VT-MIPM-135-D. |
9392 | Log Viewer | Fixed log viewer crashing issue when reading records from the ST-IPM-6350. |
9406 | Tool Kit | Fixed range selection drop-down list for E2/EB-MIX24882 counter channels. |
8996 | Tool Kit | Eliminate error message if automatic update web site is not accessible. |
7090 | Firmware Loader | Update firmware loader version to 1.13. |
8837 | Tool Kit | When tag names are auto-generated, consolidate double underscores. |
9412 | Installation | Always include the HTML Help control. |
8871 | Installation | In Windows 7, automatically configure Tool Kit for XP SP3 compatibility. |
8684 | Help | Include "AlarmConfigurationHelp.pdf" document in Tool Kit installation. |
3.52.114
2012-01-19
ID | Subject | Description |
---|---|---|
7128 | ISaGRAF | Enabled export from a VT-IPm2m-113 and VT-IPm2m-213 to ISaGRAF v3.x workbench. |
ID | Subject | Description |
---|---|---|
8615 | SIVM | Added help for the SIVM configuration pages. |
8762, 8586 | Tool Kit | Fixed bug that caused data corruption and loss while saving ET-MIX24880-D remote link information. |
7090 | Firmware Loader | Fixed the Firmware Loader Search Options dialog so it will now retain the selection settings. |
8812 | ISaGRAF | Fixed bug that caused the error message "Unable to connect, Dialog with Resource failed" when attempting to download a new project to an RTU. |
8732 | Datalogging | Fixed issue that caused the datalog information to be shifted into the wrong columns. |
8516 | Datalog Server | Added the Citect Datalog Server to the Tool Kit installation. |
8678 | Tool Kit | Fixed bug that would cause SIVM tag descriptions to appear in Station Status Module and Module Status Module tags. |
8685 | Tool Kit | Fixed bug in the connection list that caused incorrect station name selections for the I/O Gateway/RTU Station connection type. |
8676 | Tool Kit | Fixed problem with the IPm configuration opening to the wrong part if the firmware loader has been used. |
8670 | Tool Kit | Fixed Ethernet settings window draw issue for EtherTRAK-2 stations using DHCP. This fixes a window drawing problem that failed to display the '--DHCP--' text for the primary interface on initial open. |
8213 | Tool Kit | Fixed EtherTRAK-2 remote I/O Links to use the correct IP address. |
8544 | Tool Kit | Fixed internal reference bug for "IPm2m Onboard I/O". |
8356 | Tool Kit | Fixed a bug that would create project file corruption that would cause an error when re-starting Tool Kit. |
8360 | Tool Kit | Enabled the menu selections for "Upgrade Firmware" and "Show DHCP Status..." if EtherTRAK-2s are selected from the tree view tabs. |
8536 | SIVM | Fixed bug that left old SIVM data in an IPm after the module was removed. |
8556 | Installer | Fixed uninstaller bug that would cause some files to be removed from the next installation of Tool Kit after a reboot. |
8599 | Tool Kit | Fixed error locating remote station IP address when the station is not using Ethernet. |
8602 | Test I/O | Fixed display of FO values in Test I/O to show zero decimal places instead of six when configured for zero. |
8621, 8622, 8623, 8624 | Tool Kit | Added module specific help for E2/EB-10RTD and E2/EB-16ISOTC. |
8630 | Tool Kit | Fixed invalid "First AO register" entry in the remote I/O analog options for E2/EB-10RTD and E2/EB-16ISOTC. |
8533 | USB | Changed USB driver .inf file and directory name to generic, "USBSerial", and fixed uninstall error. |
8359 | ISaGRAF | Fixed ISaGRAF v3.47 communications bug that displayed 'Error Creating Notification Thread'. |
8372 | Tool Kit | Fixed bug that prevented disabling physical input reads for IPm stations. |
8371 | Tool Kit | Fixed bug that caused a base EEROM write failure on VT-MIPM-131-D. |
8368 | Tool Kit | For RTUs, list module numbers in sorted order in the selection combo box. |
8407 | ISaGRAF | Fixed bug that included disabled tags in ISaGRAF export (false overlapped I/O error). |
8411 | Tool Kit | Fixed problem with SIVM register start values being recalculated. |
8369 | Tool Kit | Restore FI, FO, LI, LO scale value editing capability. |
8267 | Tool Kit | Fixed bug in support of 0-20 mA AO configuration for E2-MIX24882. |
8326 | Tool Kit | Fixed bug that would automatically add a prefix to a copy of a module/station that had none. |
8215 | ISaGRAF | Fixed Link Setup not retaining the station number. |
3.51.123X
2011-10-11
ID | Subject | Description |
---|---|---|
8201 | Tool Kit | Fixed Tool Kit crashing when the user double-clicks in the RTU configuration's "Files to Load" or "User Software" lists. |
7931 | Tool Kit | Fixed appearance of duplicate I/O transfers via remote link. |
3.51.122X
2011-10-10
ID | Subject | Description |
---|---|---|
7941 | SIVM | Fixed the SIVM display of wrong values for "Flow control" and "restart reason". |
3.51.121X
2011-10-06
ID | Subject | Description |
---|---|---|
7978 | SIVM / Test I/O | Fixed the display of LI and FI units for the SIVM in the Test I/O window. |
3.51.120X
2011-10-05
ID | Subject | Description |
---|---|---|
8204 | Tool Kit | Support 0-20 mA AI configuration in Tool Kit for E2/EB-MIX24882. |
ID | Subject | Description |
---|---|---|
8214 | Tool Kit | Fixed duplicate I/O tag error which occurred even when tag restrictions were disabled. |
7979 | Test I/O | Fixed Eth1 speed and status so they are not blank for the VT-MIPM-245-D. |
3.51.119X
2011-10-03
ID | Subject | Description |
---|---|---|
7924 | SIVM | Fixed fluctuating AI-0 values when a SIVM is deleted from an existing configuration and loaded. |
8211 | SIVM/ISaGRAF | Added SIVM reset with each station configuration load. |
7879 | Tool Kit | Fixed the starting address for DO in MIX modules. |
8196 | Tool Kit | Fixed saving of analog scaling information for combination I/O modules. |
8109 | Tool Kit | Initially select "Output" in calibration if module is only AO. |
7317 | Tool Kit | Fixed display of I/O transfers "To Discrete Out"/"To Analog Out" local start values. |
3.51.117X
2011-09-26
ID | Subject | Description |
---|---|---|
7949 | Tool Kit | Fixed crash issue when project file may contain invalid tags. |
7887 | Tool Kit | Fixed crash issue when Analog Output Module type selected. |
3.51.116X
2011-09-20
ID | Subject | Description |
---|---|---|
8110 | Tool Kit | Fixed I/O transfer settings for ISO modules. |
3.51.115X
2011-09-16
ID | Subject | Description |
---|---|---|
7753 | Tool Kit | Added six32com.exe to display in About box. |
7781 | Tool Kit | Add message to discrete tabs if no discretes are available. |
ID | Subject | Description |
---|---|---|
7090 | Firmware Loader | Firmware load issue with v1.11 loader. Would not find firmware if using a .zip. |
3.51.111
2011-09-06
ID | Subject | Description |
---|---|---|
7479 | Configuration | Fixed crash when trying to copy a station. |
7781 | Configuration | Fixed blank analog and discrete tags for 16ISO20M. |
7713 | Configuration | Fixed blank tag description for Analog I/O on E2 modules. |
7801 | Help | Fixed issue where version reported under help can be one greater than the version in the installer. |
7744 | OEM | Added some OEM P/N's. |
7775 | Redundancy | Fixed Tool Kit crash on second deselection of redundancy. |
3.50.088
2011-08-12
ID | Subject | Description |
---|---|---|
7524 | OEM | Improved OEM rebranding flexibility. |
ID | Subject | Description |
---|---|---|
7512 | EtherTRAK-2 | Fixed bug that always showed high speed counter 4 enabled after performing a read back operation. |
7366 | SIVM | Fixed bug that did not save the reset enable. |
6520 | Ring Switch Monitoring | Default tag names are now consistent with naming used in other areas of the Tool Kit. |
7516 | SIVM | Changed SIVM port names in port status section to match spec. |
7471 | EtherTRAK | Fixed EtherTRAK configuration load failure when unit is at factory defaults. |
7507 | Licensing | Fixed a bug where registered add-ons could be lost in some cases. |
7577 | SIVM/Redundancy | Fixed duplicate tags when using Redundancy with a SIVM by removing the automatic tag assignments. |
7291 | ISaGRAF/OEM | Updated publisher name and values to correct versions. |
7142 | Registration | Fixed some awkward wording and generally improved the text. |
7341 | SIVM | Added more meaningful value labels to the status registers. |
7345 | Help | Fixed copyright attribution in Test I/O's Help/About. |
7575 | Install | Fixed warning messages during DNP3 installation. |
7152 | USB | Fixed reinstall of USB driver after manually deleting it from devices manager and then reinstalling the Tool Kit. |
7166 | UI | Fixed issue with overlapping window buttons when installing E2-16ISO20M modules. |
6523 | Test I/O | Fixed issue where E2/EB-16ISOTC modules display large values on disabled channels. |
7689 | Communications | Fixed issue with communications manager locking communications in some cases. |
7707 | Configuration Loading | Fixed bug which would reset the IPm after every config load. Now only does it if needed. |
7735 | Redundancy | Setting redundant IP address of 0.0.0.0 (empty address) now works. |
7707 | Configuration | Fixed issue which would reset the unit on every config load. |
3.50.080
2011-07-26
ID | Subject | Description |
---|---|---|
7515 | SIVM | Fixed bug that resulted in wrong tag names when changing the number of registers. |
6935 | SIVM | Fixed bug that resulted in empty tag names when adding from context menu. |
5775 | Calibration | Fixed reset problems when exiting the calibration wizard. |
3.50.078
2011-07-01
ID | Subject | Description |
---|---|---|
7239 | EtherTRAK-2 | Added 2 additional high speed counters to E2-MIX24882 (total of 4). Requires module hardware revision 0102. |
ID | Subject | Description |
---|---|---|
7372 | Counter Time Base | Fixed bug that overwrote counter time bases when changing sink/source settings. |
7341 | SIVM | Fixed minor bug that displayed scaled min/max values for discrete tags. |
7322 | SIVM | Fixed bug that failed to write [port status] values when I/O Transfers use station number instead of name. |
7063 | I/O Transfers | I/O Transfers to remote I/O modules were not loaded with the correct IP address. |
7197 | Auto-Open Feature | If the previous file was removed and the 'Auto-Open Last Project File' was enabled, the Tool Kit would crash. |
6945 | SIVM | The [port status] section was not written when empty. |
3.50.068
2011-05-27
ID | Subject | Description |
---|---|---|
7105 | Port Configuration | After loading firmware, port settings may have failed to load depending on timeout value. |
3.50.067
2011-06-02
ID | Subject | Description |
---|---|---|
6660 | SIVM | Added SIVM. Requires IPm firmware 4.2.1014 and module daemon. |
6636 | 0-20 mA Analog Outputs | Added 0-20 mA capability to m2m-213 and E2-MIX24882 for analog outputs. Requires IPm firmware 4.2.1014 and E2 firmware 1.11. |
6660 | SIVM | Added 'Redundancy Role' to redundancy module. This is used by the SIVM. |
ID | Subject | Description |
---|---|---|
6856 | Repair Old Install Issues | Upon running the .067 install, previous install and uninstall issues will be repaired. 'Control Panel -> Add or Remove Programs' list is cleaned of dead links. |
3.50.056
2011-04-28
ID | Subject | Description |
---|---|---|
6813 | ISaGRAF Options | Fixed bug that failed to store and read hot restart options. |
6806 | ST-MIX-12884 Counters | Fixed bug that loaded 'Count Up' type only for ST-MIX-12884. |
6802 | m2m and combination I/O | Fixed bug that left AO ranges at defaults (10V). 4-20 mA range is now loaded. |
6790 | Uninstall | Fixed problem with slashes in 'I/O' paths which prevented the uninstall from completing properly. |
6731 | Test I/O | Fixed bug Test I/O that displayed the wrong units for rate counters. |
6694 | EtherTRAK-2 Web UI | Fixed bug in loading from the Tool Kit which resulted in the Web UI showing incorrect tag names. |
6670 | EtherTRAK-2 | EtherTRAK-2 station names were not enforced to be unique which caused DAO errors. |
6656 | Remote I/O Links | Fixed bug that failed to remove remote I/O links when the target EtherTRAK-2 was deleted. |
6489 | Import | EtherTRAK-2 stations were missing from the 'I/O Definitions' import. |
5737 | Project Files | Fixed bug that crashed the Tool Kit when opening a read-only file. |
6741 | Install | Fixed missing .customize files for DNP3, AGA, and IEC60870. |
6693 | EtherTRAK-2 | Fixed bug that crashed the Tool Kit when reducing the number of I/O in an EtherTRAK-2 station. |
6719 | IPm2m | Fixed register shifting bug when the on-board I/O module is not the first in the list. |
3.50.045
2011-04-01
ID | Subject | Description |
---|---|---|
6596 | RTU | Added capability to monitor ISaGRAF. See the advanced tab of an IPm station configuration. |
ID | Subject | Description |
---|---|---|
6471 | IPm2m | Fixed AO register range problem in calibration of IPm2m (-213). |
6412 | IPm2m | Fixed bug that prevented the high speed counter option for IPm2ms. |
6400 | Sixlog | Fixed read back bug that resulted in corrupt record content configurations. |
6387, 5985 | Install | Fixed uninstall warning messages. The Tool Kit is now using the NullSoft (NSIS) installer. |
6385 | Sixlog | Fixed crash when stations report an error during reading of records. |
6384 | IPm2m | Fixed bug that resulted in invalid analog tag names/ranges for AO registers. |
6368 | ST-GT-1210 | FTP and Telnet options were incorrectly available in the UI. |
6287 | Watchdog | Fixed bug that failed to save the freeze/drop settings under watchdog settings. |
6174 | Remote I/O Links | Fixed bug that only included 8 counters for EtherTRAK-2 MIX modules (corrected to 16). |
5983 | Install | Fixed bug that requested a disk during repair option. The Tool Kit is now using the NullSoft (NSIS) installer. |
3.50.043
2011-03-13
ID | Subject | Description |
---|---|---|
6365 | Uninstall | Fixed uninstall error/warning that .tlb files did not unregister. |
3.50.042
2011-03-09
ID | Subject | Description |
---|---|---|
6368 | ST-GT-1210 | Fixed FTP and Telnet options bug that allowed them to be selected although not supported. |
6399 | IPm2m | Fixed bug that shifted analog output tags in project files previous to v3.50.042. |
6412 | IPm2m | Fixed bug where first channel not selectable as HS counter. |
6471 | IPm2m | Fixed calibration for m2m analog outputs (range and register number). |
3.50.041
2011-02-23
ID | Subject | Description |
---|---|---|
6123 | RTU | Fixed missing sink/source option for mix modules and mini/micro IPms. |
6350 | IPm2m | Fixed bug that loaded datalog configurations to flash instead of /nvram. |
6235 | EtherTRAK-2 | The 'Specify an IP address' option now uses the specified IP instead of switching to the new IP address. |
6174 | EtherTRAK-2 | Remote I/O links to EtherTRAK-2 mix modules now use 16 counters instead of the 8 previously assigned. |
3.50.038
2011-02-07
ID | Subject | Description |
---|---|---|
6164 | RTU | Added capability to freeze/drop and manual control with watchdog. |
ID | Subject | Description |
---|---|---|
6094 | RTU | Loading with incompatible communications settings caused the Tool Kit to appear to be locked up. |
6184 | RTU | Removed 256 I/O point limitation from all IPm products. |
6166 | IPm2m | Watchdog settings were not being displayed correctly. |
6225 | Datalog Server | Fixed bug that caused serial port transfers to be missed by the server. |
6235 | EtherTRAK-2 | When using 'Specify an IP' option in device setup, the station load operation will now use this IP for the entire process. |
3.50.031
2011-01-14
ID | Subject | Description |
---|---|---|
6013 | E2-16DORLY | Added the 16 channel relay module to the Tool Kit. |
ID | Subject | Description |
---|---|---|
5480 | Datalog Server | First set of records were being discarded. |
6025 | Find Ethernet Stations | The search was not finding stations on the network. |
3.50.028
2010-12-16
ID | Subject | Description |
---|---|---|
5741 | Redundancy | Added support for Dual LAN Redundancy. A common IP address can be added to each interface of an ST-IPm. |
ID | Subject | Description |
---|---|---|
5934 | EtherTRAK-2 | Fixed raw min/max value bug when changing ranges in ISOTC module. |
5887 | Citect Export | The browse button would not work if the Tool Kit could not find the folder in the registry. |
5787 | Tool Kit | Fixed memory leak. |